Key features:
- Wide range of input optical power
- System of automatic output power stabilization
- High output level
- Built-in equalizer
- Compact die-cast housing
- Modification (SUO1035) with UPS available
On demand
Price Options
On demand
On demand
Add to cart
Need a consult?
Our experts will answer any technical question
Ask a question
SUO1005/1035 Optical Nodes
are designed for operation in FTTH/FTTP networks, for example in RFoG networks. The Nodes allow sharing one optical fiber for reception and conversion of optical signal into RF signal in forward path, and conversion of RF signal into optical signal and its transmission in return path. The device does not require maintenance and is suitable for round-the-clock operation. The receiver part of the Node ensures operation at low levels of optical power, which allows for significant reduction of the number of active network components and thus improves its reliability.
SPECIFICATIONS | ||
Model | SUO1005 | SUO1035 |
FORWARD PATH | ||
Optical wavelength | 1550±10 nm | |
Input optical power | -6 to +2 dBm | |
Optical return loss | 35 dB | |
Equivalent input noise current | 5.5 pA/√Hz | |
Frequency range | 75 to 1005 MHz (optional) | |
Flatness | ±0.75 dB | |
Max output level CTB/CSO (42 ch, CENELEC) | 98/98 dBµV | |
Level adjustment range | 0 to 20 dB | |
Equalizer adjustment range | 0 to 20 dB | |
RETURN PATH | ||
Frequency range | 5 to 55 MHz (optional) | |
Flatness | ±0.5 dB | |
Input level range
| 70 to 90 dBµV
| |
Level adjustment range | 0 to 12 dB | |
Noise factor | 6 dB | |
Return loss | 18 dB | |
Laser type | DFB | |
Optical wavelength | 1310±40 nm | |
Output optical power | 1 mW | |
Output optical power stability | ±1 dB | |
Laser operating mode | Burst mode | |
Switchover time between modes | 1.5 µs | |
GENERAL FEATURES | ||
Mains voltage | ~187 to 244 V | |
Power consumption | 12 W | |
Dimensions | 155х115х60 mm | |
Temperature range | -20 to +55 °C | |
Optical connector | SC/APC (optional) | |
Connector type | F-female | |
Signal attenuation at test point | 20 dB | |
Battery capacity* | - | 7 A/h (12 V) |
Battery life** | - | 12 hours |
Battery charging time** | - | 20 hours |
Protection class according to IEC529 | IP40 | |
* - optional ** - for 7 A/h 12 V battery |
PLANAR also offers KR 7-12 Power Set, which includes:
- 7-12 Battery
- Battery mounting bracket
- Clamping