- Operating frequency range: from 1 MHz to 6 GHz
- Measured parameters: S11, cable loss
- Impedance: 50Ω
- Number of ports: 1
- Dynamic range: not less than 109 dB
- Measurement time at one frequency: 100 µs
- Output power adjustment range: from -40 to 0 dBm
- Measurement of S11, |S21|, |S12|, S22 (when using 2 reflectometers)
- Connection to devices without a measuring cable
- Compact and lightweight
1 year warranty
Need a consult?
Our experts will answer any technical questionThe vector reflectometer (vector network analyzer) CABAN R60 is designed to measure the magnitude and phase of the reflection coefficient, the magnitude of the transmission coefficient (when using 2 reflectometers), and cable losses in the frequency range from 1 MHz to 6 GHz. The CABAN R60 provides laboratory-level performance in a portable device. This vector reflectometer can be connected directly to the device under test without the need for a microwave measurement cable, eliminating measurement errors. As a result, high reliability and calibration stability are ensured.
Application
Due to its measurement accuracy, ultra-compact size, and absence of a microwave measurement cable, the vector reflectometer CABAN R60 can be used for equipment tuning in field conditions, as well as in laboratory and production tests in various industries, including the development and production of various IoT (Internet of Things) hardware components, materials science, medicine, aerospace industry, and more.
If you would like to consult with our engineers regarding the application of the vector reflectometer CABAN R60 in your project, please use the "Ask a Question" form.
Software
The vector reflectometer CABAN R60 includes a radio frequency measurement module and comes with RVNA software compatible with the Windows operating system. Upon request, device software for Linux OS is provided. The software can be installed on a computer, laptop, or tablet, which in turn connects to the reflectometer via a USB interface.Operating Frequency Range | 1 MHz to 6 GHz |
Number of Measurement Ports | 1 |
Type of Measurement Port Connectors | N, plug |
Wave Impedance of Measurement Ports, Ohms | 50 |
Measured Parameters | S11, cable losses S11, |S21|, |S12|, S22 (when using 2 devices) |
Output Power Level Setting Range, dBm | from -40 to 0 |
Dynamic Range*, dB, minimum | 109 |
Number of Measurement Points per Scan | from 2 to 100,001 |
Minimum Measurement Time at One Frequency, µs | 100 |
Minimum Frequency Step Size, Hz | 20 |
Measurement Filter Bandwidth (with a 1/3 coefficient), Hz | from 10 to 100,000 |
Power Supply | from USB interface |
Operating Ambient Temperature Range, °C | from -10 to +50 |
Dimensions (L×W×H), mm, maximum | 161×65×28 |
Weight, kg, maximum | 0.35 |
* with an intermediate frequency filter bandwidth of 10 Hz
Name |
Quantity, pcs |
Vector Reflectometer |
1 |
USB Cable |
1 |
Software |
1 |
User Manual |
1 |
Calibration Methodology |
1 |
Form |
1 |
Notes:
Specific model of the vector reflectometer is determined upon ordering.
Accessories such as measurement adapters and calibration tools are supplied upon separate order.