- Dynamic Measurement Range: up to 130 dB
- Output Power: up to 14 dBm
- Models with Electronic Attenuator
- Number of Ports: up to 4
Warranty: 1 year
Need a consult?
Our experts will answer any technical questionFEMs can be used for measuring filters, in antenna measurements, and for on-wafer probing. Continuous signal and modulated carrier operation modes are available.
Modifications of FEMs with built-in attenuators, VECTOR-A, allow adjusting the output power in the range of up to -40 dB (typ. -50 dB), enabling measurement of active devices (amplifiers, LNAs), including compression point, automatically.
The modules cannot operate autonomously; they must be connected to the network analyzer to conduct measurements.
FEMs can be used with network analyzers from third-party manufacturers when powered by an external power supply (separate item in the order).
Characteristic | VECTOR 50 - 75 GHz | VECTOR 75 - 110 GHz | VECTOR 110 - 170 GHz |
Frequency Range, GHz | 50 - 75 | 75 - 110 | 110 - 170 |
Typical Output Power VECTOR, dBm | +14 | +11 | in the process of matching |
Typical Output Power VECTOR-A, dBm | +12 | +9 | in the process of matching |
Dynamic Range with IF Filter Bandwidth 10 Hz, dB | 120 | 120 | 110 |
Attenuator Tuning Range, dB | 0 to -40 | 0 to -40 | 0 to -40 |
Measuring Port Connector Type | WR15, UG-385/U | WR10, UG-387/U-M | WR6, UG-387/U-M |
Dimensions, mm | 220 x 105 x 80 | 220 x 105 x 80 | 220 x 105 x 80 |
Weight, kg | 3.5 | 3.5 | in the process of matching |
Continuous Operation Time, hours | 16 | ||
Measuring Port Connector Type | WR-15 IEEE 1785-2a compatible with UG-385/U | WR-10 IEEE 1785-2a compatible with UG-387/UM | WR-06 IEEE 1785-2a compatible with UG-387/UM |
Connector Type for "RF", "LO", and "IF" Inputs | SMA (socket) | SMA (socket) | SMA (socket) |
Connection to VNA for control and power supply, connector type and protocol | LEMO B-series (Lemo 2B FGG.310), SPI protocol | ||
Power Supply | +12 V at 1 A | ||
Power Consumption, W | 12 | ||
Dimensions (L x W x H), mm | 220 x 105 x 80 | ||
Weight, kg | 3.5 | ||
Operating Conditions: | +5 .. +40 / 90 / 70 .. 106 |
Characteristics measured after 1-hour warm-up and 1 hour after calibration.
Name |
Quantity |
Note |
Frequency Range Expansion Module |
1 |
|
Control Cable |
1 |
Length 2.0 m |
RF Cable: SMA, plug - SMA, plug |
1 |
Length 1.2 m |
LO Cable SMA, plug - SMA, plug |
1 |
Length 1.2 m |
Coaxial Transition with 3.5 mm Connectors (socket - socket) |
1 |
|
IF Cable SMA, plug - SMA, plug |
2 |
Length 1.2 m |
Set of Bolts for Waveguide Flange Connection (8 pieces) |
1 |
|
Hex Screwdriver 2 |
1 |
|
Formulary |
1 |
|
VECTOR-KN waveguide calibration kit |
optional |