- Wide input measuring range: 40–126 dBuV
- Frequency range: 5–865MHz
- When works in return path analysis set:
- measures pilot signals of GPS-01 generators
- searches active GPS-01s
- measures spectrum of a return path
- measures frequency response of a return path
- receives auxiliary information from GPS-01s
- transmits results of all measurements through a forward path
- Measurement in the forward path:
- levels of carriers, carrier/noise, carrier/audio
- spectrum with a different frequency span
- Generator can work in three modes:
- generation of unmodulated signal
- generation of pilot-signals
- generation of scanning signal for measuring of frequency response function
- The mode of GPS-01 is set with the computer, IT-081 or a built-in user interface
The monitor is intended for measuring of pilot-signals, injected by the GPS-01s, frequency response function and spectrum in the cable segment in the return band with. Results of measurements are displayed on a built-in screen and transmited through the forward path to IT-081.
GPS-01 Return path pilot generator.
GPS-01 forms signals for measuring frequency response function, for installation and control of the cable network state.
IT-081: TV level meter.
The TV level meter IT-081 performs measuring of TV signals parameters of 5 to 900 MHz range. IT-081 displays measurement results when it operates with the set.
- The set is intended for installation purposes and maintaining of TV cable network with return band
- The set allows to measure:
- frequency response function of return band in the cable TV network
- spectrum of return and forward path bands
- frequency response function of return band in the cable TV network
- All measurements are displayed on CIU’s screen and derived by IT-081 connected to any point of network
Specification |
|
Frequency range |
5 - 65 MHz |
Frequency resolution |
125 kHz |
Level measurement range |
40 - 126 dBuV |
Level measurement accuracy |
±2 dB |
Measuring time of pilot-signals |
<1,2 sec |
Measuring time of frequency response |
<2,5 sec |
Spectrum measuring time in over the range |
<15 sec |
Frequency range of dates transfer |
400 - 450, or 108-135 MHz |
Powered by |
220V ± 22V AC |
Set functioning
The generator GPS-01 connects to a cable network point where it needs to correct level or control frequency response of return path. The mode of GPS-01 is set with a computer, IT-081 or a built-in user interface. It is possible to change number of pilot-signals (up to 4) and tune pilot signal frequencies in the 5 to 65 MHz range. Signals output levels are adjusted in the 72 to 118 dBuV range with the 0,75 dB step. Pilot-signals are generated consequently in time. Every signal contains a name code of generator and some auxiliary information. Moreover GPS-01 can work in a frequency scanning mode and an unmodulated single-tone mode. All parameters of the generator are saved during power switch-off.
The monitor CIU-01 is installed in a head-end according to a current network configuration. After finding out the active pilot-generator and defining his signals frequencies, CIU-01 starts to measure pilot signal levels. After that searching of new pilot-generators, measuring both signals levels and a spectrum of return path is performed simultaneously. It is possible to have up to 8 active GPS-01 in the same network but pilot signals frequencies values have to differ each other. Results of measuring are transmitted back through the forward path.
The TV level meter IT-081, connected in any cable network point, receives data from CIU-01 and displays it. It is possible to watch a spectrum of return path or pilot signals levels of any active GPS-01.
The CIU measurement results can be read in via RS-232 interface for automatic monitoring over the cable network performance, statistics acquisition, real-time measurements and documenting the results. Documentation on the CIU communications protocol is provided upon request.