- Dynamic Range: up to 130 dB
- Output Power: up to 14 dBm
- Models with Electronic Attenuator
- Number of Ports: up to 4
Warranty: 1 year
Need a consult?
Our experts will answer any technical questionFEMs can be used for measuring filters, in antenna measurements, and for on-wafer testing. Continuous signal and modulated carrier operation modes are available.
Modifications of FEMs with built-in attenuators, VECTOR-A, allow adjusting the output power in the range of up to -40 dB (typ. -50 dB), enabling measurement of active devices (amplifiers, LNAs), including compression point, automatically.
The modules cannot operate autonomously; they must be connected to the network analyzer to perform measurements.
FEMs can be used with network analyzers from third-party manufacturers when powered by an external power supply (separate item in the order).
| Characteristic | VECTOR 50-75 GHz | VECTOR 75-110 GHz | VECTOR 110-170 GHz |
| Frequency range | from 50 to 75 GHz | from 75 to 110 GHz | from 110 to 170 GHz |
| VECTOR Output power (typ.) | +14 dBm | +10 dBm | -2 dBm |
| VECTOR Output power, | +12 dBm | +8 dBm | -4 dBm |
| Dynamic range with 10 Hz IF filter bandwidth (typ.) | 120 dB | 120 dB | 110 dB |
| Attenuator tuning range | from 0 to -35 dB | from 0 to -35 dB | from 0 to -35 dB |
| Test port connector | WR-15, UG-385/U | WR-10, UG-387/U-M | WR-6, UG-387/U-M |
| Dimensions | 347 × 140 × 93 mm | 347 × 140 × 93 mm | 287 × 120 × 93 mm |
| Weight | 3.3 kg (116.4 oz) | 3.3 kg (116.4 oz) | 3.3 kg (116.4 oz) |
| Continuous operation time | 16 hours | ||
| Connector type | WR-15 IEEE 1785-2a compatible with UG-385/U | WR-10 IEEE 1785-2a compatible with UG-387/UM | WR-06 IEEE 1785-2a compatible with UG-387/UM |
| Input connector type “RF”, “LO” and “IF” | SMA (female) | SMA (female) | SMA (female) |
| Connection to VNA for control and power, connector type and protocol | LEMO B-series (Lemo 2B FGG.310), protocol SPI | ||
| Power | +12 V at 1 A | ||
| Power consumption | 12 W | ||
| Dimensions (L x W x H), mm | 220 x 105 x 80 | ||
| Weight, kg | 3.5 | ||
| Operating Conditions: | +5 .. +40 / 90 / 70 .. 106 | ||
Characteristics measured after 1-hour warm-up and 1 hour after calibration.
|
Name |
Quantity |
Note |
|
Frequency Range Extansion Module |
1 |
|
|
Control Cable |
1 |
Length 2.0 m |
|
RF Cable: SMA, male - SMA, male |
1 |
Length 1.2 m |
|
LO Cable SMA, male - SMA, male |
1 |
Length 1.2 m |
|
Coaxial Transition with 3.5 mm Connectors (female-female) |
1 |
|
|
IF Cable SMA, male - SMA, male |
2 |
Length 1.2 m |
|
Set of Bolts for Waveguide Flange Connection (8 pieces) |
1 |
|
|
Hex Screwdriver 2 |
1 |
|
|
Documentation |
1 |
|
|
VECTOR-KN waveguide calibration kit |
optional |