Software option “Measurement of converters parameters” (MXR)
- MXR-9 - for devices with a frequency range of up to 9 GHz
- MXR-20 - for devices with a frequency range of up to 20 GHz
Frequency conversion devices (mixers, converters, etc.) are key components of any communication system. Since their input and output frequencies differ, the VNA must have the appropriate functions and capabilities to measure their characteristics. Two main methods are used for measurements: scalar and vector.
Scalar measurement method
The method provides accurate measurements of the transmission coefficient module and complex reflection parameters by using the frequency offset mode. The advantage of this method is a simple measurement setup without the use of external additional equipment.
Scalar mixer measurements are used to test the basic performance parameters (matching, conversion loss, compression, isolation). These traditional measurements require two steps: first measuring the RF input power, then measuring the IF output power.
Vector measurement method
The method allows measuring in vector form both reflection parameters and transmission parameters, including phase and group delay time of the transmission coefficient. This method requires additional equipment: an external mixer with a filter, called a calibration mixer, and a heterodyne signal source common to the mixer under study and the calibration mixer.
Automatic frequency offset adjustment
The function provides automatic adjustment of the VNA port offset frequency to the output frequency of the device under study. The function is used when there is no possibility of synchronizing an external heterodyne signal source and the VNA, as well as when measuring devices with a built-in heterodyne.
Application:
- Mixer parameters measurements (step-up and step-down frequency converters, multi-stage converters)
- Frequency multipliers/dividers/parameters measurements
- Harmonic measurements (including the ability to look at parasitic harmonics)
- Intermodulation distortion measurements
- MXR-20 - for devices with a frequency range of up to 20 GHz
Frequency conversion devices (mixers, converters, etc.) are key components of any communication system. Since their input and output frequencies differ, the VNA must have the appropriate functions and capabilities to measure their characteristics. Two main methods are used for measurements: scalar and vector.
Scalar measurement method
The method provides accurate measurements of the transmission coefficient module and complex reflection parameters by using the frequency offset mode. The advantage of this method is a simple measurement setup without the use of external additional equipment.
Scalar mixer measurements are used to test the basic performance parameters (matching, conversion loss, compression, isolation). These traditional measurements require two steps: first measuring the RF input power, then measuring the IF output power.
Vector measurement method
The method allows measuring in vector form both reflection parameters and transmission parameters, including phase and group delay time of the transmission coefficient. This method requires additional equipment: an external mixer with a filter, called a calibration mixer, and a heterodyne signal source common to the mixer under study and the calibration mixer.
Automatic frequency offset adjustment
The function provides automatic adjustment of the VNA port offset frequency to the output frequency of the device under study. The function is used when there is no possibility of synchronizing an external heterodyne signal source and the VNA, as well as when measuring devices with a built-in heterodyne.
Application:
- Mixer parameters measurements (step-up and step-down frequency converters, multi-stage converters)
- Frequency multipliers/dividers/parameters measurements
- Harmonic measurements (including the ability to look at parasitic harmonics)
- Intermodulation distortion measurements