- VNA Performance Test software allows automatic verification and calibration of PLANAR vector network analyzers with the required set of accessories
- All methods are validated and tested in type approval tests.
- Built-in instructions allow you to perform any measurements without referring to operating manuals or other documents
- Depending on the selected operation, the program automatically sets the device parameters. Random operator actions cannot lead to a failure in operation, distortion or loss of measurement results.
- The statement on compliance is generated automatically based on the results of each operation.
- The presentation form of the results is universal and complies with the recommendations of international documents on metrology.
- The obtained results can be saved to a file and/or printed in the form of a protocol.
Automation of the measurement process
Vector network analyzers are designed to measure complex transmission and reflection coefficients (elements of the scattering matrix) of multiport devices. The devices differ from each other in the upper limit of the operating frequency range, the number of measuring ports, the presence of connectors for direct access to the inputs of measuring and reference receivers, and the presence of connectors for connecting frequency extenders.
Field of application: testing, tuning, research and development of various radio devices in industrial production and laboratories, and as part of automated measuring systems.
VNA Performance Test software has been specially developed to perform measurements in automatic mode. Automation of measurements reduces the time of instrument verification, reduces the operator's workload and reduces the risk of performing actions that may lead to distortion or loss of measurement results.
PLANAR Vector Network Analyzers
Vector network analyzers manufactured by PLANAR are divided into four series depending on their purpose, technical characteristics and functional capabilities: СOBALT, OBZOR, COMPACT and CABAN.
Regardless of the series, all devices are further divided into four groups: R, SN, S2 and S4:
- Group R – 1-port vector network analyzers (reflectometers);
- Group S2 – 2-port devices measuring full matrix of S-parameters;
- Group SN – 4/8/10/12/14/16- port devices measuring full matrix of S-parameters;
- Group S4 – 4-port devices measuring full matrix of S-parameters.
Each group of R, SN, S2 and S4 devices is controlled by separate software RVNA, SNVNA, S2VNA and S4VNA respectively. Each of these applications contains a COM server that allows other third-party programs to access its functions. Automation of devices requires that the COM server be registered in the computer operating system.
Verification and calibration in automatic mode
List of supported tests:
- relative accuracy in setting the output signal frequency;
- relative accuracy in setting the output power level;
- relative level of harmonic components of the output signal spectrum;
- relative level of non-harmonic components of the output signal spectrum;
- standard deviation of the trace;
- receivers' own noise level;
- uncorrected parameters;
- absolute measurement accuracy of the module and phase of the reflection coefficient (direct method, comparison method);
- absolute measurement accuracy of the module and phase of the transmission coefficient (direct method, comparison method).
Sequence of actions
1 Connecting the device to a computer via USB
2 Installing control software. Registering a COM server. Launching the software.
3 Installation of VNA Performance Test. Launching the software.
4 Selecting a device from those connected to the computer
5 Choice of method (direct or comparison method)
6 Carrying out testing according to built-in instructions. Saving the measurement protocol
Sequence of actions when working with VNA Performance Test:
- Connect the device to the computer using a USB cable.
- Install the driver and control software if they were not previously installed, register the COM server.
- Launch the control software. Check that after a few seconds the status bar shows "Ready".
- Install VNA Performance Test if it is not installed previously. Follow the wizard instructions during installation.
- Run VNA Performance Test, the program should automatically detect the devices connected to the computer; if necessary, click the "Update" button.
- Enter the protocol file name and the operator's personal data.
- Select a device from the list and click the "Run" button.
- Select the testing method depending on the means used.
- Follow the software instructions to complete the specified test points.
- Save measurement results in PDF format or print.
When taking measurements, follow the instructions in the built-in manual.
The VNA Performance Test software contains all the necessary instructions and measurement diagrams. Depending on the test being performed, VNA Performance Test automatically sets the analyzer parameters, such as frequency range, number of frequency points, output power level, and intermediate frequency filter bandwidth. Accidental user actions will not cause a malfunction, distortion, or loss of measurement results.
Help file
The VNA Performance Test program has a help file. This file can be opened using standard Windows tools.
The help file contains:
- description of the user interface
- system requirements
- instructions for each device
- reference information on the verification or calibration tools used, auxiliary equipment and required measurement conditions.
To get acquainted with the operation of the VNA Performance Test program, you can use the DEMO version of the software.
VNA Performance Test Software
- VNA Performance Test software allows automatic verification and calibration of PLANAR vector network analyzers with the required set of accessories
- All methods are validated and tested in type approval tests.
- Built-in instructions allow you to perform any measurements without referring to operating manuals or other documents
- Depending on the selected operation, the program automatically sets the device parameters. Random operator actions cannot lead to a failure in operation, distortion or loss of measurement results.
- The statement on compliance is generated automatically based on the results of each operation.
- The presentation form of the results is universal and complies with the recommendations of international documents on metrology.
- The obtained results can be saved to a file and/or printed in the form of a protocol.
Automation of the measurement process
Vector network analyzers are designed to measure complex transmission and reflection coefficients (elements of the scattering matrix) of multiport devices. The devices differ from each other in the upper limit of the operating frequency range, the number of measuring ports, the presence of connectors for direct access to the inputs of measuring and reference receivers, and the presence of connectors for connecting frequency extenders.
Field of application: testing, tuning, research and development of various radio devices in industrial production and laboratories, and as part of automated measuring systems.
VNA Performance Test software has been specially developed to perform measurements in automatic mode. Automation of measurements reduces the time of instrument verification, reduces the operator's workload and reduces the risk of performing actions that may lead to distortion or loss of measurement results.
PLANAR Vector Network Analyzers
Vector network analyzers manufactured by PLANAR are divided into four series depending on their purpose, technical characteristics and functional capabilities: СOBALT, OBZOR, COMPACT and CABAN.
Regardless of the series, all devices are further divided into four groups: R, SN, S2 and S4:
- Group R – 1-port vector network analyzers (reflectometers);
- Group S2 – 2-port devices measuring full matrix of S-parameters;
- Group SN – 4/8/10/12/14/16- port devices measuring full matrix of S-parameters;
- Group S4 – 4-port devices measuring full matrix of S-parameters.
Each group of R, SN, S2 and S4 devices is controlled by separate software RVNA, SNVNA, S2VNA and S4VNA respectively. Each of these applications contains a COM server that allows other third-party programs to access its functions. Automation of devices requires that the COM server be registered in the computer operating system.
Verification and calibration in automatic mode
List of supported tests:
- relative accuracy in setting the output signal frequency;
- relative accuracy in setting the output power level;
- relative level of harmonic components of the output signal spectrum;
- relative level of non-harmonic components of the output signal spectrum;
- standard deviation of the trace;
- receivers' own noise level;
- uncorrected parameters;
- absolute measurement accuracy of the module and phase of the reflection coefficient (direct method, comparison method);
- absolute measurement accuracy of the module and phase of the transmission coefficient (direct method, comparison method).
Sequence of actions
1 Connecting the device to a computer via USB
2 Installing control software. Registering a COM server. Launching the software.
3 Installation of VNA Performance Test. Launching the software.
4 Selecting a device from those connected to the computer
5 Choice of method (direct or comparison method)
6 Carrying out testing according to built-in instructions. Saving the measurement protocol
Sequence of actions when working with VNA Performance Test:
- Connect the device to the computer using a USB cable.
- Install the driver and control software if they were not previously installed, register the COM server.
- Launch the control software. Check that after a few seconds the status bar shows "Ready".
- Install VNA Performance Test if it is not installed previously. Follow the wizard instructions during installation.
- Run VNA Performance Test, the program should automatically detect the devices connected to the computer; if necessary, click the "Update" button.
- Enter the protocol file name and the operator's personal data.
- Select a device from the list and click the "Run" button.
- Select the testing method depending on the means used.
- Follow the software instructions to complete the specified test points.
- Save measurement results in PDF format or print.
When taking measurements, follow the instructions in the built-in manual.
The VNA Performance Test software contains all the necessary instructions and measurement diagrams. Depending on the test being performed, VNA Performance Test automatically sets the analyzer parameters, such as frequency range, number of frequency points, output power level, and intermediate frequency filter bandwidth. Accidental user actions will not cause a malfunction, distortion, or loss of measurement results.
Help file
The VNA Performance Test program has a help file. This file can be opened using standard Windows tools.
The help file contains:
- description of the user interface
- system requirements
- instructions for each device
- reference information on the verification or calibration tools used, auxiliary equipment and required measurement conditions.
To get acquainted with the operation of the VNA Performance Test program, you can use the DEMO version of the software.