S4VNA software
S4VNA software is designed to work with analyzers:
Compact series: S50444
Cobalt series: С1409, С1420, С2409, С2420, С4409, С4420
Standard software features of S4VNA software include:
- measurement of S-parameters (S11, …, S44), absolute power
- linear, logarithmic, segment sweep by frequency with various trace formats
- linear sweep by power range
- up to 16 channels, each channel up to 16 traces
- maximum number of measurement points from 200 001 to 500 001
- power control with level and slope adjustment for each port
- display of memory traces with the ability to save up to 8 memory traces
- start sweep cycle (trigger source: external, internal or software)
- synchronization of external devices in the sweep cycle
- mathematical operations with traces, autoscaling of traces, correction of electrical delay
- calibrations – reflection and transmission normalization, SOL, two-port one path, two/three/four-port SOLT and TRL – using mechanical standard kits defined by the model or data, or ACM. Power calibration and receiver calibration
- up to 16 markers, marker search and marker math functions
- data analysis functions (port extension, Port Z conversion, de-embedding and embedding, S-parameter transformation)
- balance measurements
- auxiliary source (Cobalt series)
- frequency range extension (C4409 и C4420)
- direct access to receivers (C4209 and C4220)
- printing and saving traces
- remote control via SCPI (TCP/IP Socket) and COM (DCOM)
Options
- DC voltage for each measured frequency point (Cobalt series)
- FIFO buffer (Cobalt series)
- time domain, time selection (option TD-20)
- measurement of frequency offset devices (MXR-20)
- pulse measurements (analyzers S50444 and S50244, option PLS(PR-001))
Compact series: S50444
Cobalt series: С1409, С1420, С2409, С2420, С4409, С4420
Standard software features of S4VNA software include:
- measurement of S-parameters (S11, …, S44), absolute power
- linear, logarithmic, segment sweep by frequency with various trace formats
- linear sweep by power range
- up to 16 channels, each channel up to 16 traces
- maximum number of measurement points from 200 001 to 500 001
- power control with level and slope adjustment for each port
- display of memory traces with the ability to save up to 8 memory traces
- start sweep cycle (trigger source: external, internal or software)
- synchronization of external devices in the sweep cycle
- mathematical operations with traces, autoscaling of traces, correction of electrical delay
- calibrations – reflection and transmission normalization, SOL, two-port one path, two/three/four-port SOLT and TRL – using mechanical standard kits defined by the model or data, or ACM. Power calibration and receiver calibration
- up to 16 markers, marker search and marker math functions
- data analysis functions (port extension, Port Z conversion, de-embedding and embedding, S-parameter transformation)
- balance measurements
- auxiliary source (Cobalt series)
- frequency range extension (C4409 и C4420)
- direct access to receivers (C4209 and C4220)
- printing and saving traces
- remote control via SCPI (TCP/IP Socket) and COM (DCOM)
Options
- DC voltage for each measured frequency point (Cobalt series)
- FIFO buffer (Cobalt series)
- time domain, time selection (option TD-20)
- measurement of frequency offset devices (MXR-20)
- pulse measurements (analyzers S50444 and S50244, option PLS(PR-001))